Mains-linked smoke & heat alarms, fire alarms, BS 5266 emergency lighting and surge protection — designed, installed and tested for homes, landlords and businesses.

Accredited & insured
NAPIT approvedNAPIT
CHAS accreditedCHAS
City & Guilds qualifiedCity & Guilds
TrustMark endorsedTrustMark
Part P registeredPart P
BS 7671 18th Edition compliantBS 7671
Board elucian labelled — DS Electrical job photo

Compliance made simple

The systems that keep people safe.

Whether it’s a landlord’s smoke-alarm duty or emergency lighting for a commercial unit, we specify to the right standard and hand over the log book and certificate.

  • BS 5839-6 smoke & heat alarms
  • Interlinked, mains-wired (Grade D LD2)
  • Fire alarm systems & panels
  • BS 5266 emergency lighting
  • Surge protection (SPD)
  • Landlord & HMO compliant

What we fit

Detection, escape, protection.

Smoke & heat alarms
01

Smoke & heat alarms

Interlinked mains alarms with sealed 10-year backup.

Surge protection
02

Surge protection

SPDs at the board to protect against surges and strikes.

Emergency lighting
03

Emergency lighting

BS 5266 escape lighting with annual duration tests.

Test & certify
04

Test & certify

Everything tested and handed over with a log book.

How it works

Specified, fitted, certified.

01AssessWe check the property against the right standard.
02SpecifyA clear plan of alarms, lighting or protection.
03InstallNeat, interlinked and mains-wired.
04CertifyTested, with the log book and certificate.

FAQ

Safety questions.

What smoke alarms do landlords need?

Most rentals need BS 5839-6 Grade D LD2 — interlinked, mains-wired smoke alarms on each storey plus heat alarms in kitchens. We fit compliant Aico/Kidde systems and certify them.

What is emergency lighting?

BS 5266 escape-route lighting that stays on if the power fails. We design, install and carry out the annual 3-hour duration test with a full log book.

Do I need surge protection?

The 18th Edition recommends SPDs in most installations. We can add surge protection at your consumer unit to protect appliances and systems.

Do I legally need a fire alarm system?

All non-domestic premises in England & Wales are covered by the Regulatory Reform (Fire Safety) Order 2005, which requires a fire risk assessment. That assessment determines whether a BS 5839-1 automatic fire detection system is needed. HMOs and rental properties fall under the Smoke and Carbon Monoxide Alarm Regulations 2022 requiring interconnected smoke and heat detection.

How often does my fire alarm need servicing?

BS 5839-1 requires a competent person to carry out quarterly inspections and a full annual service. We offer both as a contracted package with certificates issued after every visit for your fire risk assessment file.

What is the difference between conventional and addressable?

Conventional fire alarm systems divide the building into zones and identify the triggered zone but not the exact device. Addressable systems identify the exact device that has activated, which saves time during evacuation and fault finding. Addressable is recommended for larger buildings, multi-storey premises, and anywhere rapid response matters.

Can you install a fire alarm in a listed building?

Yes. We install wireless and hybrid addressable systems (Hochiki EKHO, Apollo MultiPoint Pro, Hyfire) that require no cabling between devices -- ideal for listed buildings where chasing cables is prohibited. We liaise with conservation officers where heritage consent is required.

My fire alarm keeps going off. Can you fix false alarms?

Yes. Most false alarms are caused by incorrect detector choice (smoke detectors near kitchens), environmental factors, or ageing devices. We survey the system, replace unsuitable detectors with multi-sensors or rate-of-rise heat detection where appropriate, and configure panel delays per BS 5839-1 Section 37.

More from DS

Other services.

All services →

Fire alarm systems

Fire alarms, done properly.

Fire alarm systems save lives — when they are designed, installed and serviced properly. We design and install BS 5839-1 compliant commercial fire alarm systems across Mid Somerset, from simple single-zone domestic systems through to multi-loop addressable panels for large commercial premises. Every system certified, every panel commissioned, every service visit logged.

01

BS 5839-1 commercial fire alarms

The standard for fire detection and alarm systems in non-domestic premises. Covers everything from the initial fire risk assessment and system category (M, L1–L5, P1–P2) through to design, installation, commissioning, certification and ongoing service. We design to BS 5839-1:2017+A2:2023 and issue the correct G1 Design, G2 Install and G3 Commission certificates at each stage.

02

Conventional vs addressable

Conventional systems split the premises into zones and a triggered device activates the whole zone. Ideal for smaller sites up to around 1,500m² — shops, small offices, single-storey premises. Typically 2–8 zones, lower cost, simpler commissioning.

Addressable systems report the exact device that has activated. Essential for larger buildings, multi-storey premises, and anywhere fast fault finding matters. Panels from Advanced MxPro, Kentec Syncro, C-Tec, Morley-IAS and Apollo. Scalable from 1 to multiple loops with hundreds of devices per loop.

03

Wireless & hybrid systems

Hochiki EKHO, Apollo MultiPoint Pro and Hyfire Taurus wireless systems let us install addressable fire detection in listed buildings, period properties and operating premises where cable runs are impossible or prohibitively disruptive. Full BS 5839-1 compliance, 10-year sealed battery life, and signal redundancy with mesh repeaters. We also deploy hybrid systems — wireless expansion onto existing wired loops for phased upgrades.

04

Domestic fire alarm (BS 5839-6)

The domestic standard, covering everything from single-dwelling smoke alarms through to Grade A interconnected systems in HMOs and student housing. Interlinked mains-powered smoke and heat detectors with 10-year sealed battery backup from Aico and FireAngel. HMO landlords: we issue the annual certificate required under HMO licensing and the Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022.

05

Manual call points, sounders, beacons

Resettable manual call points (MCPs) with protective covers to prevent accidental activation. Conventional and addressable sounders and sounder/beacons to BS EN 54-3 and 54-23 respectively — with output levels calculated to reach at least 65 dB(A) in every part of the premises (or 75 dB(A) at the bedhead in sleeping accommodation). Voice-sounder (VAD) systems available for high-occupancy premises and premises where standard tone sounders are inadequate.

06

Smoke, heat & multi-sensor detection

Optical smoke detectors for general fire detection, ionisation detectors for fast-flaming fires, heat detectors for kitchens and dirty environments, beam detectors for large open spaces, aspirating smoke detection (Wagner, Vesda) for server rooms and archives, and multi-sensor detectors that combine optical and heat for lower false-alarm rates. Every detector sited per BS 5839-1 Annex B.

07

Annual service & quarterly inspection

BS 5839-1 Section 6 requires a competent person to carry out quarterly inspections (Section 45) and a full annual service (Section 44). We deliver both as a contracted service: every device tested, every sounder level verified, every call point operated, batteries tested under load, logbook updated, and a certificate issued for your fire risk assessment and insurance file. If anything fails we fix it the same day where practical.

08

False alarm reduction

Somerset Fire & Rescue now charge for repeated false alarm call-outs, and persistent false alarms can invalidate your insurance. We reduce false alarms by reviewing detector siting (removing smoke detectors from steam-prone kitchens and replacing with rate-of-rise heat detectors), fitting multi-sensor detectors in marginal environments, adding delay-to-confirm on panels, and implementing staff verification procedures compliant with BS 5839-1 Section 37.

09

Fire alarm cable & containment

Fire-rated FP200 Gold, Firetuff or Prysmian FP PLUS cable for all fire alarm wiring — BS EN 50200 PH30/PH60/PH120 survivability to match the category of system. Containment in galvanised steel conduit or tray where required, fire-rated intumescent seals at all compartment wall and floor penetrations, and proper segregation from other services per BS 5839-1 Section 26. We do not use standard twin-and-earth for fire alarm cabling. Ever.

10

Certification & compliance

Every installation comes with the full set of certificates required by BS 5839-1:

  • G1 — Design certificate: issued by the designer confirming the system meets the design objectives and category
  • G2 — Installation certificate: issued by the installer confirming the system was installed to the design
  • G3 — Commissioning certificate: issued after final testing confirming all devices operate correctly
  • G4 — Acceptance certificate: signed by the user
  • G5 — Verification certificate (where required by a third party)
  • Service and test certificates after every planned visit

All documentation logged and available to your insurer and local fire authority on request.

Commercial fire alarm control panel with sounder and manual call point, installed by DS Electrical Installations (SW) Ltd

On the wall, on the certificate

Wired, commissioned and certified.

Commercial fire alarm install: panel, manual call point, red beacon and compliant signage. BS 5839-1 commissioning certificate issued on handover.

See our work →

The certification ladder

From enquiry to certified install.

Every project follows the same five-step process. No surprises, no scope creep.

01Fire risk assessment reviewWe review your existing FRA (or commission one with our partner assessor) and map it to the BS 5839-1 category needed: M, L1–L5 or P1–P2.
02Design + G1 certificateSystem designed on paper: panel type, device count, cable routes, sounder coverage, power supply sizing. G1 Design certificate issued.
03Install + G2 certificateFP200 Gold or equivalent cable, proper segregation, devices sited per BS 5839-1 Annex B. G2 Installation certificate issued on completion.
04Commission + G3 certificateEvery device activated and tested. Sounder output levels measured. Panel programmed. G3 Commissioning certificate signed off.
05Service contractQuarterly inspections and annual service scheduled immediately. Logbook supplied. Certificates lodged for your fire risk assessment file.

Areas we cover

Fire alarms across Mid Somerset.

What customers say

★★★★★
“I had a brilliant experience using Dan for a full revamp of the electrics ready for the new kitchen. It was a large project and he explained things clearly and gave me options.”
Nicola Laing · Google review
★★★★★
“Dan and his team did a fantastic job upgrading everything in my flat. Professional, tidy, and excellent quality work throughout.”
Catherine Wyatt · Google review
★★★★★
“Dan arrived on time, completed the job in a professional and speedy way. There was no mess to clean up. I would highly recommend.”
Verified Client · Checkatrade
Read all reviews →

Get a quote

Make it safe.

Alarms, emergency lighting or surge protection — tell us the property and we’ll advise.

  • NAPIT registered & TrustMark accredited
  • Fully insured, every job certified
  • Free, no-obligation quotes
  • Mid Somerset & surrounding areas

Prefer to talk? Call DS Electrical Installations (SW) Ltd on 07889 334849.

Thanks — that’s sent.

DS Electrical Installations (SW) Ltd will call you back to talk through the job.