Garden lighting design and install, IP65 luminaires, 12V SELV low-voltage systems, mains SWA runs, PIR floodlights, smart-control integration. NAPIT, BS 7671. Garden lighting for Shepton Mallet (BA4), BS 7671 18th edition, NAPIT-certified, Part P notified. Every garden is different, so we price each one individually and confirm a fixed quote in writing.
Or WhatsApp: wa.me/447889334849



Garden lighting design and install, IP65 luminaires, 12V SELV low-voltage systems, mains SWA runs, PIR floodlights, smart-control integration. NAPIT, BS 7671. Every job is BS 7671 18th edition certified and Part P notified through NAPIT.
Full service detail on our parent Garden Lighting page.
Shepton Mallet (BA4) is industrial-edge Somerset, Royal Bath & West Showground, working farms, light-industrial estates around Townsend and Cannards Grave, plus stone cottages and Georgian terraces in the town centre. Mixed-use stock: agricultural, light commercial, period domestic.
Many jobs around Shepton Mallet involve farm or workshop loads, single phase up-rated to 3-phase, sub-mains across yards in SWA, agricultural sockets. We're set up for the right cabling and IP-rating from the start.
Sister city pages: EICR in Shepton Mallet · Rewires in Shepton Mallet
No two gardens are the same, so we don't publish a price list. Access, cable routes, the existing wiring and the size of the scheme all affect the price. We look first, then give you a fixed written quote.
Yes. We do farm wiring, workshop sub-boards, SWA submains across yards, agricultural-rated sockets and showground temporary supplies. Everything compliant with BS 7671 Section 705 (agricultural) and properly IP-rated for the environment.
Yes. We integrate garden lighting with Philips Hue Outdoor, Loxone, Tuya, Lutron and most major smart-home systems. Typical setups give per-zone control, scenes (dinner, security, off), sunset/sunrise schedules and PIR-overrides. We install the gateway, commission the zones and label everything in your hub before we leave.
Yes, every external circuit needs 30mA RCD protection (typically per-circuit RCBO at the consumer unit), and mains cables run outdoors must be SWA armoured or in mechanical protection. Low-voltage 12V SELV systems are inherently safer (lower shock risk) and don't need RCD protection on the secondary side, but the 230V transformer feed always does.
Tell us a little about the job in Shepton Mallet and we will ring you back to talk it through.
Site survey, fixed-price written quote, full BS 7671 certification. Call us on 07889 334849.
07889 334849Same trusted DS Electrical service across our other Somerset coverage areas.