BA3 · RCBO boards only · Part P notified

Consumer unit replacement in Radstock

We replace old fuse boxes and early RCD boards across Radstock with a metal consumer unit, a main switch and a Type A RCBO on every circuit, so one fault no longer takes out half the house.

Priced on your property, fixed in writing after we have seen the board.

New consumer unit with a row of RCBOs and a surge protection device fitted by DS Electrical

Why Radstock homes are changing their boards

If your Radstock house still has a board with wire fuses, plug-in fuses or a single RCD feeding every socket, it was fitted to an older standard. It may still work. The problem is what happens when something goes wrong: an old fuse may not disconnect quickly enough on a fault, and a single shared RCD means a faulty kettle can switch off the freezer, the lights and the boiler at the same time.

We only fit one type of board: a metal consumer unit with a double-pole main switch and a Type A RCBO on every circuit. Each RCBO combines overcurrent protection and residual current protection for its own circuit, so a trip stays local. We do not fit split-load or dual-RCD boards, at any price.

Before we quote we check what the board is feeding. Changing the board means testing every circuit connected to it, and a board change on top of wiring that fails insulation tests is money wasted. If the circuits are poor we tell you, and give you the cost of the board and the cost of the wiring work as separate figures.

What we find behind Radstock fuse boards

Many of the town’s terraces were built for colliery families when Radstock was the centre of the Somerset coalfield, and their boards often sit in a cupboard under the stairs or high above the front door next to the meter. Space is tight, and the meter tails are sometimes too short or too thin to reach a new board in the same spot. We allow for new 25mm² flexible tails in every quote where they are needed.

The other common finding is missing or undersized main bonding to the incoming gas and water pipes. A new board does not fix that by itself, so where bonding is missing we include it in the price and show it as its own line.

Houses on the 1970s estates around Westfield usually have a board in the hall or garage with a mix of rewireable fuses and later additions. Those boards often have no spare ways, which is why extra circuits for a shower or garage have been bolted on beside them. A new RCBO board brings everything back into one enclosure.

What a Radstock board change includes

Every board we fit is tested and certified, and the job is notified to Building Control through NAPIT.

How we price consumer unit replacement in Radstock

The price depends on the number of circuits, the state of the existing wiring, and whether tails or bonding need replacing. We look first, at a survey or from a phone and photo consultation, then quote a fixed price in writing with VAT on a separate line. Quotes are free.

Get a quote

How a board change runs

A standard board change is a single day. The power is off for most of it, so we plan around you.

  1. We test the existing circuits first, so there are no surprises once the old board is off the wall.
  2. The supply is isolated and the old board removed.
  3. The new board is fixed, each circuit is connected to its own RCBO, and the tails and bonding are dealt with.
  4. Every circuit is tested again, results are recorded, and the power is restored circuit by circuit.
  5. You get the certificate by email, and the Building Regulations certificate follows by post.
Close view of RCBOs wired in a new consumer unit
RCBOs wired in a new board. Each circuit has its own device, so a fault on one does not trip the rest.

Board changes in the villages around Radstock

Outside the town we change boards in Writhlington, Clandown, Haydon and Kilmersdon, and in the BA2 villages of Peasedown St John, Camerton, Dunkerton and Timsbury. Farmhouses and older cottages in those villages often have a separate supply to outbuildings, and we include those circuits in the test.

If you are in Midsomer Norton, our consumer unit replacement page for Midsomer Norton has more on the estate houses there.

Get a price for a new board

A photo of your current board helps us price it. Send the form and we will call back, or WhatsApp the photo to 07889 334849.

Prefer to talk? Call DS Electrical on 07889 334849.

Consumer unit questions from Radstock

Do I need a new consumer unit if my house passed its last EICR?
Not necessarily. An older board can still be satisfactory. Many people change it anyway because a board with no RCD protection on the sockets usually gets a code on the next report, and an RCBO board stops one fault from switching off the whole house.
Why only RCBO boards?
Because each circuit gets its own protection. With a split-load or dual-RCD board, one fault trips every circuit on that side. With an RCBO per circuit, only the faulty circuit goes off. It is the only type of board we fit.
Will my old wiring pass the tests for a new board?
We find out before we start. If a circuit has very low insulation resistance or no earth, it will cause problems on a new board. We tell you what we found and give you the price to fix it as a separate line.
Can the board be moved?
Usually, yes. Moving it a short distance, for example out of a damp cupboard or away from the front door, is common. The meter position is set by your supplier, so the new tails have to reach from there.
Do I get a certificate?
Yes. You get an Electrical Installation Certificate for the board change, and because it is notifiable work we register it with Building Control through NAPIT. The Building Regulations certificate is posted to you.

Other services in Radstock

Ready to replace the board?

Send a photo of your current board and the number of bedrooms, and we will come back with a price.

07889 334849
Send an enquiry WhatsApp Email us
5.0
Google rating · 24 reviews
18
Years experience
NAPIT
Approved contractor 66245
£2M
Public liability cover
Call Dan07889 334849 WhatsApp Email
Call Dan: 07889 334849