Bathroom circuits in Frome (BA11), Section 701 zone planning, IP44+ everywhere, every circuit 30mA RCD-protected, electric showers, heated towel rails, IP-rated lighting, shaver sockets and extractors. Frome bathroom electrician for converted-mill apartments and period properties, Section 701, IP44+, RCD-protected, NAPIT-certified. Pricing is tailored to each bathroom, confirmed as a fixed written quote.
Or WhatsApp: wa.me/447889334849



Bathroom circuits in Frome (BA11), Section 701 zone planning, IP44+ everywhere, every circuit 30mA RCD-protected, electric showers, heated towel rails, IP-rated lighting, shaver sockets and extractors. Frome bathroom electrician for converted-mill apartments and period properties, Section 701, IP44+, RCD-protected, NAPIT-certified. Pricing is tailored to each bathroom, confirmed as a fixed written quote.
Full service detail and the eight-circuit kitchen brief on our parent Bathroom Electrics page.
Frome has a heavy stock of converted mills and warehouse apartments, bathrooms in these conversions often span exposed brick walls, suspended slabs and tight service voids. Section 701 zoning still applies; the challenge is routing IP-rated cable cleanly without spoiling the loft aesthetic.
Georgian and Victorian terraces around Catherine Hill have small period bathrooms with tight zones and original lath-and-plaster ceilings, we work surface-clip or chase carefully where conservation allows.
Frome is 25 minutes from our base, we cover the BA11 postcode regularly and survey within the week for most enquiries.
Sister city pages: EICR in Frome · Rewires in Frome
Every Frome bathroom is priced individually. Access, cable routes, the existing wiring and whether the room is being refurbed at the same time all change the price, so we survey first and then fix the price in writing. The survey is free.
Yes, we work with the suspended slabs and exposed-brick aesthetic. Cables run in service voids or surface conduit to suit the look, IP44+ everywhere, RCD-protected, full Section 701 zone compliance. Minor Works or EIC issued.
Single-circuit jobs (extractor, towel rail, shaver, mirror) are 1 day. A shower circuit replace is normally 1 day. A full bathroom rewire (extractor, lighting, shaver, towel rail, shower) is 2-3 days for first-fix and 1 day for second-fix after the tiling is in.
Section 701 of BS 7671 is the special-locations chapter for rooms with baths and showers. It defines Zones 0, 1 and 2 around the bath/shower and dictates IP rating and what fittings are permitted in each zone. Zone 0 is inside the bath itself (12V SELV only). Zone 1 is above the rim (IP65, 30mA RCD). Zone 2 is the area within 0.6m of zone 1 (IP44 minimum). Outside zones is 'general' but RCD protection is still required on every circuit serving the bathroom.
Leave a name and number and we will call back to talk it through. Quotes are free.
Site survey, fixed-price written quote, full BS 7671 Section 701 certification. Call us directly on 07889 334849.